GE 45606 Switch User Manual


 
LED Light
When shipped from the factory, the LED on the 45606 is set to turn
ON when the connected light is turned OFF. This allows the LED
to indicate the switch’s location in a dark room. To make the LED
turn ON when the light is turned ON, change parameter 3’s value
to “1”.
- Parameter No: 3
- Length: 1 Byte
- Valid Values = 0 or 1 (default 0)
Invert Switch
If the dimmer switch is accidentally installed upside down with
“On” at the bottom and “Off” at the top, the default On/Off rocker
settings can be reversed by changing parameter 4’s value to “1”.
- Parameter No: 4
- Length: 1 Byte
- Valid Values = 0 or 1 (default 0)
Dim Rate Adjustments
Both the number of steps (or levels) that the dimmer will change
and the timing of the steps can be modified to suit personal
preferences. The timing of the steps can be adjusted in 10
millisecond intervals. As an example, the default setting for
parameter 8 is “3”. This means that the lighting level will change
every 30 milliseconds when the Dim Command is received. A
value of 255 would mean that the level would change every
2.55 seconds. Combined, the two parameters allow dim rate
adjustments from 10 milliseconds to 4.2 minutes to go from
maximum-to-minimum or minimum-to-maximum
brightness levels.