Installation Instructions
Electrical Connections cont.
B6
Three-Conductor Branch
Circuit Connection
When connecting to a three-conductor branch circuit,
if local codes permit:
a. Connect the bare oven ground conductor with the
crimped neutral (white) lead to the branch circuit
neutral (white or gray in color), using a wire nut.
b. Connect the oven red lead to the branch circuit
red lead in accordance with local codes, using a
wire nut.
c. Connect the oven black lead to the branch circuit
black lead in accordance with local codes, using a
wire nut. If the residence red, black or white leads
are aluminum conductors, see WARNING on
page 10.
d. Install Junction Box Cover.
B3
New Construction and
Four-Conductor Branch
Circuit Connection
When installing in new construction, or
When installing in a mobile home, or
When installing in a recreational vehicle, or
When local codes do not permit grounding through
neutral:
a. Cut the neutral (white) lead from the crimp.
Re-strip the neutral (white) lead to expose the
proper length of conductor.
b. Attach the appliance grounding lead (green or
bare copper) in accordance with local codes. If the
residence grounding conductor is aluminum, see
WARNING on page 10.
c. Connect the oven neutral (white) lead to
the branch circuit neutral (white or gray) in
accordance with local codes, using a wire nut.
d. Connect the oven red lead to the branch circuit
red lead and the oven black lead to the branch
circuit black lead in accordance with local codes,
using wire nuts. If the residence red, black or
white leads are aluminum conductors, see
WARNING on page 10.
e. Install Junction Box Cover.
B
Ground
Wire
Junction Box
Cover
BARE
COPPER
16AWG
BLACK
16AWG
BLACK
GROUND
RED
16AWG
RED
WHITE
(NEUTRAL)
16AWG
WHITE
UL APPROVED
CONNECTOR
UL APPROVED
JUNCTION BOX AND COVER
#12-#10 AWG COPPER
NMD90 WIRE. FUSE 20
AMP CIRCUIT BREAKER
TO BREAKER PANEL
CONDUIT
FROM
OVEN
This oven is supplied with a 48 (123 cm)
long flexible conduit consisting of:
3 insulated conductors (copper)
1 bare ground conductor (copper)
Attach conductors to residence wiring as
shown by wiring diagram.
B5
B4
Junction Box
Cover
Ground and
Neutral Wires