Graco 15V336 Network Router User Manual


 
Installation
Connections
Make electrical and communication connections to
the AWI.
To avoid electric shock, turn off power before
servicing.
Shut off power at main circuit breaker.
All electrical wiring must be done by a qualified
electrician and comply with all local codes and
regulations.
1. Connect the AWI to power.
a. Connect main power supply cord (A, not
supplied) through the strain relief to terminals
L1 (+) and N (-) on the power supply (4).
b. Connect power cord ground wire C) to the
terminal block (13).
2. Connect the AWI to another Graco device or
gateway and to a PC.
a. Shut off power to the Graco device (D). Also
shut off power at main circuit breaker.
b. Run a CAT5 cable through grommet from the
ethernet port on the Graco device or gateway
(D) and connect it to any port on the ethernet
switch (10) in the AWI .
c. Run another CAT5 cable from any port on
the ethernet switch (10) to the ethernet port
on a PC (E).
Key Conections and
Installation Example
Supplied in AWI Module
4
POWER SUPPLY, 24 Vdc
5
GROMMET, cable entry
6
CONNECTOR, strain
relief
10
SWITCH, ethernet
13
BLOCK, terminal, ground
G
AWI Module
Accessories or
User-Supplied Components
A
Power Cord, user
supplied
B
Cable, CAT 5, user
supplied
C Ground wire from power
cord
D
Graco device or gateway
E Personal computer
F Fiber optic cable
HAWIHub
J
Informer Module
K
ProControl 1KE Module
6 332459A