Graco 15V534 Network Router User Manual


 
Installation
313212A 9
Connect the Gun Flush Box
NOTE: Use 5/32 in. (4 mm) OD tubing to connect the
gun flush box air ports to the interface module air ports,
as follows. See F
IG. 12.
1. From the P port to the air supply.
2. From the A port to the pressure switch air input.
3. From the C port to the gun flush box solenoid out-
put.
4. From the S port to the atomizing air safety shutoff
valve pilot port. See the gun flush box manual for
details on the safety shutoff valve.
5. From the AFS to the atomizing air safety shutoff
valve IN port. See the gun flush box manual for
details on the safety shutoff valve.
Connect Air Supply to Module
Connect a 1/4 in. (6 mm) OD tube between a clean, dry
air supply (filtered to 10 microns) and the module air
inlet fitting (13). See Parts on page 11.
Replace the Cover
Reinstall the cover on the enclosure and secure with the
four captive screws.
Ground the Enclosure
Connect a ground wire (Y) from the enclosure’s ground
screw (6) to a true earth ground. See F
IG. 11.
F
IG. 11. Ground the Enclosure
6
Y
TI14277a
FIG. 12: Gun Flush Box to Interface Module Air Connections
P
A
C
S
TI14278a
P
A
C
S
PC
AFS
IN
GUN FLUSH BOX
INTERFACE MODULE
AIR SAFETY
SHUTOFF VALVE
TI13110b