Graco 24B596 Network Card User Manual


 
Setup
18 313855H
8. If the PIN Code you entered is correct, the System
Setup Screen, shown in F
IG. 22 displays.
9. If the PIN Code you entered is incorrect, the digits
flash. The Code must be re-entered by repeating
steps 4 and 5.
NOTE:
As soon as any arrow key is pressed, the numerals
stop flashing.
To leave any Setup Screen and return to normal
operation, press RESET.
System Setup
Main Screen
1. Use the UP/DOWN arrows to move the cursor up
and down through the list of setup screens (F
IG. 22).
2. Press ENTER to display the selected setup screen.
3. When all setup operations are complete, press
RESET to return to normal operation.
PUMP ON Setup
Pump On is the length of time the pump runs before its
cycle is terminated by either a timer, a specific number
of cycles or a certain pressure threshold is attained.
1. Use the UP/DOWN Arrow keys to move the cursor
over PUMP ON.
2. Press ENTER to display the PUMP ON setup
screen.
TIMER Setup
NOTE: Time is displayed in HH:MM:SS.
1. Use the Arrow keys to move the cursor over the
PUMP ON time box.
2. Press ENTER.
3. Use the UP/DOWN arrows to move up and down
through the numbers 0-9 until the first number in the
PUMP ON time is displayed in the field.
4. Use the RIGHT arrow to move the cursor to the next
field.
5. Repeat steps 3 and 4 until the desired time is dis-
played.
6. Use the Arrow keys to move the cursor over the
ENDED BY pull-down list.
F
IG. 22
FIG. 23
F
IG. 24