Graco 24B596 Network Card User Manual


 
Run Mode
313855H 31
Pump On Ended with Cycle Switch
Activation
If the Pump On sequence has been programmed to end
by a Cycle Switch Activation:
The GLC 4400 pump output relay activates (J7-3)
and will stay on until the correct number of cycle
switch closures is received (J6-3) (see Setup
Menus, Cycle End Setup page 19).
The Pump On LED (A) remains on during this time.
The Pump On (C) icon displays.
The Cycle LED (B) and Cycle Count Mode icon (D)
display indicating the cycle switch is activated.
The cycle indicator bar (E) displays a visual repre-
sentation
of the cycle switch closures received.
If the set number of cycle switch closures is not
received before time expires, an alarm occurs.
Pump Off Ended with Time
If the Pump Off sequence has been programmed to be
ended by TIME:
The GLC 4400 pump output relay activates (J7-3)
and will stay off until the time expires. (see Setup
Menus, Pump Off, page 20).
The Pump On LED (A) remains off during this time.
The Pump Off icon (C) displays.
The Timer Mode icon (D) displays and indicates the
Timer Mode.
Pump Off Ended with Machine Counts
If the Pump Off sequence has been programmed to be
ended by MACHINE COUNTS:
F
IG. 58
A
B
C
E
D
FIG. 59
F
IG. 60
A
D
C
A
B
C
D