INTELLIFIRE (IPI) MODELS ONLY
Cold Climate Button
• Button Press: Turns on Climate Control
• Button Press: Turns off Climate Control
This allows the pilot ame to stay lit when activated, a ben-
e t of this is reduced condensation on the glass at start-up
in colder climate conditions.
Operation Under Battery Power
A switch on the control box allows for battery power under
no-power conditions (see Figure 8). By controlling the
power supply with this switch, the batteries are supplying
power only when needed, thus extending battery life. The
switch also provides a convenient means for switching to
battery power should there be a loss of 110 VAC power to
the control box.
• In the event of a power failure, switch the battery
operation switch to the “Battery ON” position.
• The replace can now be turned on and off with the ON/
OFF rocker switch located near the gas valve.
• The wall switch functions will not operate under battery
power.
• Under battery control the only available function is ame
“On” and “Off” in the high position.
• To maximize battery life, and to restore full function
capability of the wall switch, ip switch to “OFF” position
after 120 VAC power is restored.
SERVICE PARTS LIST
Child Proof Mode
To Enter Child Proof Mode:
Press the Up Arrow Button twice and Down Arrow Button
once. The unit will send out 3 beeps and an indicator in
the LCD panel will show that the child proof is on.
To Leave Child Proof Mode:
Press the Up Arrow Button twice and Down Arrow Button
once. The unit will send out 3 beeps and the indicator in
the LCD panel that shows that the child proof is on will
disappear.
Figure 8
DESCRIPTION SERVICE PART NO.
SOLENOID HTI-17-006
WALL SWITCH/KEY PAD HTI-12-007
CONTROL WIRE HTII-23-007
COVER PLATE HTI-21-007
CONTROL BOX HTI-13-007
ACTUATOR PINS HTI-17-116
SWITCH KIT HTI-25-007
BATTERY
OPERATION
SWITCH
“BATTERY ON”
POSITION
POSITION
CONTROL
BOX
“OFF”
NOTE: When in Child Proof Mode, only the arrow buttons
will have functionality. Unit can enter Child Proof when the
replace is on or off.