HP (Hewlett-Packard) 2626-PWR Switch User Manual


 
PoE Event Log Messages
PoE operation generates these Event Log messages. You can also configure
the switch to send these messages to a configured debug destination (terminal
device or SyslogD server.
I 1MM/DD/YY HH:MM:SS chassis:
Message header, with severity, date, system time, and system
module type. For more information on Event Log operation, refer
to the “Troubleshooting” appendix in the Management and
Configuration Guide for your switch.
Ext Power Supply connected, supplying< actual-power > W of
< avail-power > W max.
The switch detected an EPS (External Power Supply) and began
receiving the wattage indicated by < actual-power >. The < avail-
power > field indicates the maximum power (wattage) the
detected EPS is capable of delivering
Ext Power Supply disconnected
The switch has lost contact with an external power supply.
POE usage is below configured threshold of <1 - 99> %
< slot-# > POE usage is below configured threshold of<1-99> %
Indicates that POE usage in the switch or indicated slot (if the
switch includes module slots) has decreased below the threshold
specified by the last execution of the global power threshold <1 - 99>
command. This message occurs if, after the last reboot, the PoE
demand on the switch exceeded the power threshold and then later
dropped below the threshold value.
Port < port-# > applying power to PD.
A PoE device is connected to the port and receiving power.
Port < port-# > PD detected.
The switch has detected a PoE device connected to the port.