HP (Hewlett-Packard) 6400CL Switch User Manual


 
2-5
Installing the Switch
Installation Procedures
Installing the Switch
1. Prepare the Installation Site
Cabling Infrastructure - Ensure the cabling infrastructure meets the
necessary network specifications. The copper ports accept CX4 cable with
Infiniband-style connectors or fiber cable using a CX4 optical media converter
(OMC). The fiber ports accept single-mode fiber optic cable with SC
connectors.
Table 2-1. Fiber-Optic Cables
Table 2-2. Copper Cables
Port Type Cable Specifications Connector
Type
Supported Length
10-GbE SR Multimode fiber-optic cable designed for Gigabit
Ethernet: 62.5/125 µm (core/cladding) diameter
or 50/125 µm, low metal content, complying with
the ITU-T G.652 and ISO/IEC 793-2 Type B1
standards.
1
SC 62.5 µm cable:
160 Mhz*km = 2-26 meters
200 Mhz*km = 2-33 meters
50 µm cable:
400 Mhz*km = 2-66 meters
500 Mhz*km = 2-82 meters
2000 Mhz*km = 2-300 meters
10-GbE LR 9/125 µm (core/cladding) diameter, low metal
content, single mode fiber-optic cables,
complying with the ITU-T G.652 and ISO/IEC 793-
2 Type B1 standards.
1,2
SC single-mode cable: 2 meters - 10 km
10-GbE ER 9/125 µm (core/cladding) diameter, low metal
content, single mode fiber-optic cables,
complying with the ITU-T G.652 and ISO/IEC 793-
2 Type B1 standards.
1,2
SC single-mode cable: 2 meters - 30 km (40
kilometers, on an engineered fiber optic
link that meets standards in the
specification).
OMC CX4 Fiber 12 fiber 50/125 µm (core/cladding) diameter,
multimode Fiber ribbon cable. 12 fiber 62.5/125
µm (core/cladding) diameter, multimode Fiber
ribbon cable is also supported.
1
MTP 1-300 meters
1
Conditioning patch cord cables are not supported.
2
Multimode cables are not supported
Port Type Cable Specifications Connector
Type
Supported Length
CX4 Speed 3.125Gbx4
(Cables compatible with the 802.1ak standard)
CX4
Infiniband-
style
0.5-15 meters