Removal and replacement procedures 65
NOTE: There may be more than one memory bus speed menu option.
DIMMs
To remove the component:
1. Power down the server (on page 27).
2. Extend or remove the server from the rack ("Remove the server from the rack" on page 28, "Extend the
server from the rack" on page 28).
3. Remove the access panel ("Access panel" on page 34).
4. Remove the PCI riser cage ("PCI riser cage" on page 44).
5. Remove the air baffle ("Air baffle" on page 49).
6. Remove the DIMM.
To replace the component, reverse the removal procedure.
Battery replacement
If the server no longer automatically displays the correct date and time, you may need to replace the battery
that provides power to the real-time clock.
WARNING: The computer contains an internal lithium manganese dioxide, a vanadium
pentoxide, or an alkaline battery pack. A risk of fire and burns exists if the battery pack is not
properly handled. To reduce the risk of personal injury:
• Do not attempt to recharge the battery.
• Do not expose the battery to temperatures higher than 60°C (140°F).
• Do not disassemble, crush, puncture, short external contacts, or dispose of in fire or water.
• Replace only with the spare designated for this product.