The following table describes TPM detection scenarios that you might encounter.
ResultScenario
A warning message appears. Select OK to continue. The
installation is not canceled.
If TPM is detected and enabled, the installation is not silent,
and a system ROM must be updated.
No warning appears. A new log file is generated
(%systemdrive%\cpqsystem\log\cpqstub.log).
If TPM is detected and enabled, the installation is silent,
the /tpmbypass switch is not given, and any firmware
updated must be applied to the server. Because the installation is silent, the installation is
terminated and cannot continue.
A warning message appears. After selecting OK, you can
continue. The installation is not canceled.
If TPM is detected and enabled with Option ROM
Measuring, the installation is not silent, and a system ROM
must be updated.
No warning appears. A new log file is generated
(%systemdrive%\cpqsystem\log\cpqstub.log).
If TPM is detected and enabled with Option ROM
Measuring, the installation is silent, the /tpmbypass
Because the installation is silent, the installation is
terminated and cannot continue.
switch is not given, and any firmware updated must be
applied to the server.
The installation occurs.If TPM is detected and enabled, the installation is silent,
the installation occurs, and the /tpmbypass switch is
supplied.
Initiating deployment
Use the HP SUM GUI to deploy SPP components in online or offline interactive modes to local or
remote hosts. For detailed instructions and prerequisites see the HP Smart Update Manager User
Guide at http://www.hp.com/go/hpsum/documentation for the appropriate version of HP SUM.
Online mode
To initiate deployment in online mode:
1. Copy the SPP to a USB thumb drive, hard drive, or file system. For instructions, see “SPP
staging procedures” (page 11).
2. Launch HP SUM from the root of the ISO:
Windows: \hp\swpackages\hpsum.exe
Linux: /hp/swpackages/hpsum
TIP: If you are updating only firmware or software, use a filter argument:
/romonly With this filter switch, HP SUM only displays firmware components needed
for installation.
/softwareonly With this filter switch, HP SUM only displays software components
needed for installation.
3. To review the EULA, locate Start.htm in the root of the ISO and open it in one of the
supported browsers.
4. Follow the instructions on the screen.
Offline mode
To initiate deployment in offline mode:
1. Copy the SPP to a USB thumb drive, hard drive, or file system. When using a USB thumb
drive, the ISO must be bootable. For instructions, see “SPP staging procedures” (page 11).
2. Boot the server to the SPP.