HP (Hewlett-Packard) QR516B Computer Accessories User Manual


 
NOTE: For configurations that are intended to have more than one host type (for example, an
ESX host and a Windows host) connected to a shared HP 3PAR StoreServ Storage HBA port via
fabric connections, see to the Heterogeneous Host Support Guide on the HP BSC website for the
required HP 3PAR StoreServ Storage port settings and interoperability considerations:
http://www.hp.com/go/bsc
NOTE: By default, the VMware ESX host supports failover. For failover support, VVs should be
simultaneously exported down multiple paths to the host. To do this, create a host definition on the
HP 3PAR StoreServ Storage that includes the WWNs of multiple HBA ports on the hostand then
export the VLUNs to that host definition.
Required
The following setup must be completed before connecting the HP 3PAR StoreServ Storage port to
a device.
Setting Up the Ports
Before connecting the HP 3PAR StoreServ Storage to a host, the HP 3PAR StoreServ Storage port
persona must be specified. To set up the HP 3PAR StoreServ Storage ports for a direct or fabric
connection, issue the appropriate set of HP 3PAR OS CLI controlport commands for each port.
For direct connections, use persona 1 with VCN disabled.
# controlport persona 1 <node:slot:port>
# controlport vcn disable -f <node:slot:port>
Verify port persona 1, connection type loop, using the HP 3PAR OS CLI showport -par command.
For a fabric connection, use persona 7 with VCN disabled.
# controlport persona 7 <node:slot:port>
# controlport vcn disable -f <node:slot:port>
Verify port persona 7, connection type point, using the HP 3PAR OS CLI showport -par
command.
Configuring the HP 3PAR StoreServ Storage Running HP 3PAR OS 2.2.x 11