HP (Hewlett-Packard) SL165Z G7 Server User Manual


 
Diagnostic tools and setup utilities 91
These diagnostics, which reside in the BIOS ROM, isolate server-related logic failures and indicate the
board or component that needs to be replaced, as indicated by the error messages. Most server
hardware failures are accurately isolated during POST. The number of tests displayed depends on the
configuration of the server.
During POST you can:
Press F10 to access the Setup Utility.
POST error indicators
When POST detects a system failure, it displays a POST error message.
POST related troubleshooting
Perform the following procedures when POST fails to run, displays error messages.
If the POST failure is during a routine boot up, check the following:
All external cables and power cables should be firmly plugged in.
The power outlet to the server should be connected and works correctly.
The server and monitor are both turned on. The bicolour status LED indicator on the front panel
must be lit up green.
The monitor's contrast and brightness settings are correct.
All internal cables are properly connected and all boards firmly seated.
The processor is fully seated in its socket on the system board.
The heat sink assembly is properly installed on top of the processor.
All memory modules are properly installed.
If you have installed a PCIe accessory board, verify that the board is firmly seated and any
jumpers on the board are properly set. Refer to the documentation provided with the accessory
board.
All internal cabling and connections are in their proper order.
If you have changed the jumpers on the system board, verify that each is properly set.