HP (Hewlett-Packard) XP12000 All in One Printer User Manual


 
Fabric zonin
g and LUN security
By using appropriate zoning and LUN security, you can connect various servers with various operating
systems to the same switch and fabric:
Storage por t zones may overlap if more than one operating system needs to share an array port.
Heterogene
ous operating systems may share a n X P a rray port if you use Secure Manager and set
the appropriate host group and mod e. All others must connect to a dedicated XP array port.
Use Secure Manager for LUN isolation when multiple hosts connect through a shared array
port. Secu
re Manager provides LUN security by allowing you to restrict which LUNs each host
can access.
QLogic and Emulex HBAs must be in separate zones (a QLogic zone and an Emulex zone )
whether t
he HBAs are in the same or separate servers.
If booting over the SAN, within a server, the booting HBAs must be from the same vendor.
Additional data storage HBAs can be from a different vendor.
Environment OS mix
Fabric zoning
LUN security
homogeneous (a single
OS type present in the
SAN)
Not required
Standalone SAN
(non-clustered)
Clustered SAN
Multi-Cluster SAN
heterogeneous (more
than one OS type
present in the SAN)
Required
Must be used when
multiple hosts or cluster
nodes connect through
asharedport
If you plan to use clustering, install and congure the clustering software on the servers. Clustering
is the organization of multiple servers into groups. Within a cluster, each server is a node.
Multiple clusters compose a multi-cluster environment. The following example shows a multi-cluster
environment with three clusters, each containing two nodes. The nodes share access to the
disk
array.
18