HP (Hewlett-Packard) XU800 Personal Computer User Manual


 
Your PC Workstation Does Not Start Correctly
Case 3 — Detected Hardware Error
14
Refer to page 21 for information about runtime error codes.
Symptom... Check that... Symptom... Check that...
RDRAM modules are correctly
installed in the RIMM sockets.
RDRAM modules are installed.
RDRAM have same speed
ratings.The part number on the
paired RDRAM modules should be
the same. If different, use the
RDRAM module delivered with
your PC Workstation. Remove the
other module.
SDRAM modules are correctly
installed.
SDRAM modules are installed.
RDRAM modules are installed in
pairs with the same capacity,
speed or part number.
First pair of RDRAM modules are
installed in sockets A0-B0.
Second pair of RDRAM modules
are installed in sockets A1-B1.
In some cases, the LCD panel
could display a smiling face, but
the system does not boot.
RDRAM modules are correctly
installed in the RIMM sockets.
Continuity modules are correctly
installed.
For information about the different memory configurations, refer to page 15.
Symptom...
Check that...
Video card is:
Present.
Seated correctly in the AGP PRO connector.
Cabled correctly.
Not defective.
Symptom... Check that...
Cables are incorrectly fitted to
the corresponding system
board connectors.
Cables are correctly connected.
If required, refer to the service label inside the cover for the system board layout.
System board switches
incorrectly set.
Refer to the service label inside the cover for correct settings.
Or, refer to “System Board Switches” on page 39.
Case 3 — Detected Hardware Error is continued on the next page
NoRIMM
ERROR !
RIMM Speed
ERROR !
No DIMM
ERROR !
Mem MisCompare
ERROR !
Info Services
HP Kayak XU800
No Video
ERROR !