36
Troubleshooting
Related Messages
When the unit's power is ON, messages such as those shown below may be displayed.
When any such message is displayed on the screen, please respond as described
below. If the same message is displayed after the treatment, or if a message other than
the following appears, please contact your dealer or service company.
Message Description
CHANGE THE LAMP
AFTER REPLACING LAMP,
RESET THE LAMP TIMER.
(*1)
Lamp usage time is approaching 2000 hours. (*2)
Preparation of a new lamp, and an early lamp change is
recommended. After you have changed the lamp, please be
sure to reset the lamp timer.
CHANGE THE LAMP
AFTER REPLACING LAMP,
RESET THE LAMP TIMER.
THE POWER WILL TURN OFF
AFTER ** hr.
(*1)
Lamp usage time is approaching 2000 hours. (*2)
A lamp change within ** hours is recommended. When lamp
usage reaches 2000 hours, the power will automatically be
turned OFF. Please change the lamp by referring to the “Lamp”
section of this manual. After you have changed the lamp,
please be sure to reset the lamp timer.
CHANGE THE LAMP
AFTER REPLACING LAMP,
RESET THE LAMP TIMER.
THE POWER WILL TURN OFF
AFTER 0 hr.
As lamp use has reached 2000 hours (*2), the power will soon
be automatically turned OFF.
Please immediately turn the power off, and change the lamp by
referring to the “Lamp” section of this manual. After you have
changed the lamp, please be sure to reset the lamp timer.
NO INPUT IS DETECTED
ON ***
There is no input signal.
Please confirm the signal input connection, and the status of the
signal source.
SYNC IS OUT OF RANGE
ON *** *****kHz *****Hz
The horizontal or vertical wavelength of the inputted signal is
outside of the response parameters of this unit.
Please confirm the specs for this unit or the signal source
specs.
CHECK THE AIR FLOW
The internal portion temperature is rising.
Please turn the power OFF, and allow the unit to cool down at
least 20 minutes. After having confirmed the following items,
please turn the power ON again.
• Is there blockage of the air passage aperture?
• Is the air filter dirty?
• Does the peripheral temperature exceed 35°C?
(*1) • Although this message will be automatically disappeared after around 3 minutes, it will be reappeared
every time the power is turned ON.
(*2) • Lamps have a finite product life. Lamps are characterized by the fact that, after long hours of usage, a lamp will no
longer light up, or the lamp will break or burst, etc. This unit is equipped with an automatic shut-down function, such that
the power will automatically be turned OFF when lamp usage time has reached 2,000 hours. Please be aware, however,
that among lamp types, there are major differences in product lifetimes; a lamp may thus fail to light even prior to the
functioning of the automatic shut-down function of this unit.
NOTE
fH fV