SCANNER OPERATION
POWER SAVE MODES
The OrbitCG has five configurable power save modes. Refer to the MetroSelect
Configuration Guide (
PN 00-02407
x
) for additional information on Power Save
Modes.
1. The Blink Power Save Mode blinks the laser OFF & ON after a configured
period of non-use.
When the scanner recognizes a bar code, the scanner will exit the blink
power save mode.
2. The Laser Off Power Save Mode turns the laser OFF after a configured
period of non-use. The motor continues to spin allowing for a faster “wake”
up time.
If the button is pressed, the scanner will “wake” from the power save mode.
3. The Laser & Motor Off Power Save Mode turns the laser and motor OFF
after a configured period of non-use.
If the button is pressed, the scanner will “wake” from the power save mode.
This mode’s “wake” time is slightly longer due to the motor’s need to restart.
4. The Dual Action Power Save Mode #1 (default mode) “blinks” the laser
OFF & ON after a configured period of non-use. The laser and motor will
then turn OFF at the next thirty-minute interval.
Example:
If the power save timeout
is set to 15 minutes.
If the button is pressed the scanner will “wake” from the power save mode.
5. The Dual Action Power Save Mode #2 turns the laser OFF after a
configured period of non-use. The motor will then turn OFF at the next
thirty-minute interval.
Example:
If the power save timeout
is set to 15 minutes.
If the button is pressed the scanner will “wake” from the power save mode.
13