Honeywell MS2322 Scanner User Manual


 
22
INSTALLATION
CABLE INSTALLATION (INTERFACE SPECIFIC)
RS485
The following steps describe how to properly install the cables for an RS485 StratosH application. The scanner must then be
configured to match the host’s RS485 parameters. Cable installation alone does not guarantee that the StratosH will communicate
properly with the host system.
Configuration bar codes are located in the MetroSelect Configuration Guide (PN 00-02407x) and the MS2xxx Stratos Series
Configuration Addendum (PN 00-02034x).
1. Turn off the host system.
2. Plug the 10-pin RJ45 end of the RS485 interface cable (PN 57-57004x-N-3) into the 10-pin socket labeled, Scanner RS232 / IBM
46xx to Host, on the bottom of the StratosH. Refer to Figure on page 23.
3. Connect the other end of the RS485 cable to communication port 9 on the host device.
Before continuing verify that the RS485 cable is connected to the appropriate interface socket on the scanner. An incorrect
cable connection can cause communication problems or potential damage to the scanner and/or terminal.
Manufacturers Note: Plugging the scanner into the serial port of the host device does not guarantee that scanned
information will appear at the host device. A software driver and correct configuration settings are also required for proper
communication to occur. When using the RS232/Full Speed USB/RS485 (-121) interface, the USB and RS485 interfaces
are not active at the same time.
4. Plug the external power supply (PN 46-46xxx*) into the 3-pin Molex socket labeled, DC Power In, on the bottom of
the StratosH.
xxx* Specifies international connection. See Optional Accessories in the Introduction section of this guide for a complete listing.
Check the AC input requirements of the power supply to make sure the voltage matches the AC outlet. The outlet should
be located near the equipment and be easily accessible.
Honeywell recommends using a switched AC outlet. The switch should be located on the operator’s side of the checkout
counter in close proximity to the StratosH to facilitate calibration and service of the unit.
5. Connect AC power to the transformer. If the AC outlet is equipped with an on/off switch, turn the power on.
6. Turn on the host system.
7. Configure the StratosH to match the host system’s RS485
parameters.
Refer to the MS2xxx Stratos Series Configuration Addendum (PN 00-02034x) under Scanner Configuration Bar Codes:
IBM 3
rd
Generation Communication Defaults and IBM 3
rd
Generation Protocols.
Additional general configuration bar codes can be found in the MetroSelect Configuration Guide
(PN 00-02407x).