35
SCANNER OPERATION
BEEPER OPTIONS AND BUTTON FUNCTIONS
Changing the Beeper Tone
Beeper tones may be configured incrementally using the following bar code. The new tone will be heard followed by a short pause.
Two more new tones will be heard signifying the new setting has been stored in memory. The silent (no beep) tone is also selectable.
³ 9 9 9 9 7 5
N
Changing the Beeper Volume
Volume levels may be configured using the volume button or incrementally using the following bar code. The new volume will be heard
followed by a short pause. Two more tones will be heard signifying the new setting has been saved in memory.
The silent (no volume) tone is also selectable.
³ 9 9 9 9 7 4
N
The Multi-Function Button
Figure 35. The Multi-Function Volume Button
Changing the Beeper Volume
A
short (<3 second) depression and the beeper volume will change.
The new volume will be heard. The silent (no beep) volume is also selectable.
Placing the Unit in Laser & Motor Off Power Save Mode
Long (>3 seconds) depression The Laser & Motor Off Power Save Mode is the only power
save mode that can be activated with the multi-function button*.
*
This feature is configuration dependent. Refer to the MetroSelect Configuration Guide
(
PN 00-02407x) under Scanner Operation: Power Save Modes to enable this feature.
Waking the Unit from All Power Save Modes
The next button depression will awaken the scanner for normal operation.
Figure 36. Changing the Beeper Volume
Figure 37. Laser & Motor Off
Power Save Move
Figure 38. Normal Operation