Honeywell MS4980 Scanner User Manual


 
8
Keyboard Wedge
1. Turn off the host device.
2. Plug the 15-pin socket end of the
cable into the 15-pin D-Type
connector on the MS4980 (see
page 4).
3. Disconnect the keyboard from the
host device.
4. Connect the “Y” ends of the
communication cable to the
keyboard and keyboard port on the
host device. If necessary, use the
male/female adapter cable supplied
with the scanner for proper
connections.
5. Plug the power supply into the power
jack on the PowerLink cable.
6. Check the AC input requirements of
the power supply to verify the
voltage matches the AC outlet. The
outlet must be located near the
equipment and be easily accessible.
7. Connect AC power to the transformer.
8. The MS4980 will start to initialize. The white and blue LED will alternately
fade on and off for approximately three seconds. When the scanner has
finished initializing, the unit will flash the white LED three times while
simultaneously beeping three times. The low intensity blue LED will remain
turned on.
9. Turn on the host device. The scanner will automatically reboot after host
device is turned on.
Important Note
Plugging the scanner into a port on the host system does not guarantee that
scanned information will be communicated properly to the host system. Please
refer to the MetroSelect Single-Line Configuration Guide or MetroSet2’s help files
for instructions on changing the scanner’s factory default configuration. The
scanner and host system must use the same communication protocols.
See caution on page 5.
Figure 7.