Honeywell MS4980 Scanner User Manual


 
26
Electrical
Input Voltage: 5.2 VDC ± 0.25V
RS232,
USB w/Power Jack,
Keyboard Wedge
USB Host Powered
Power:
Peak
2.1 W (Typical) 1.9 W (Typical)
Operating 1.7 W (Typical) 1.7 W (Typical)
Idle 1.2 W (Typical) 1.2 W (Typical)
Current:
Peak
398 mA (Typical) 360 mA (Typical)
Operating 331 mA (Typical) 317 mA (Typical)
Idle 230 mA (Typical) 230 mA (Typical)
Peak Values of at least 1 ms in width.
DC Transformers: Class II: 5.2VDC @ 1 A
For Regulatory Compliance Information see pages 37 – 40.
Environmental
Temperature:
Operating = 0°C to 40° (32° to 104°F)
Storage = -20°C to 70°C (-4°F to 158°F)
Humidity: 5% to 95% relative humidity, non-condensing
Light Levels: Up to 100,000 Lux (9,290 footcandles)
Shock: Designed to withstand 1.5 m (5 ft.) drops
Contaminants: Sealed to resist airborne particulate contaminants
Ventilation: None required
Specifications are subject to change without notice.