Honeywell VX6 Laptop User Manual


 
Connect Vehicle 12-80VDC Connection
1. The VX6 must be turned off and the power cable must be UNPLUGGED from the VX6.
2. While observing the fuse requirements specified above, connect the power cable as close as possible to the actual
battery terminals of the vehicle. When available, always connect to un-switched terminals in vehicle fuse panel, after
providing proper fusing.
ATTENTION: For uninterrupted power, electrical supply connections should not be made at any point after the ignition
switch of the vehicle.
3. Route the power cable the shortest way possible. The cable is rated for a maximum temperature of 105°C (221°F).
When routing this cable it should be protected from physical damage and from surfaces that might exceed this
temperature.
Do not expose the cable to chemicals or oil that may cause the wiring insulation to deteriorate.
Always route the cable so that it does not interfere with safe operation and maintenance of the vehicle.Use proper
electrical and mechanical fastening means for terminating the cable. Properly sized “crimp” type electrical terminals are
an accepted method of termination. Please select electrical connectors sized for use with 18AWG (1mm
2
) conductors.
Wiring color codes for Honeywell supplied DC input power cabling:
Vehicle Supply Wire Color
+12 - 80VDC (DC +) White
Return (DC -) Black
Vehicle Chassis GND Green
4. Provide mechanical support for the cable by securing it to the vehicle structure at approximately one foot intervals,
taking care not to over tighten and pinch conductors or penetrate outer cable jacket.
5. Refer to the following sections to complete the power connection to the VX6.
4-3