IBM 6569 Personal Computer User Manual


 
Diagnostic Error Code FRU/Action
001-027-XXXSystem Configuration/Setup error
1. Run Setup
2. Flash the system
3. System board
001-032-XXXSystem Device Controller failure
1. System board
001-034-XXXSystem Device Buffer Allocation
failure
1. Reboot the system
2. Flash the system
3. Run memory test
4. System board
001-035-XXXSystem Device Reset condition
detected
1. System board
001-036-XXXSystem Register error
1. System board
001-038-XXXSystem Extension failure
1. Adapter card
2. System board
001-039-XXXSystem DMI data structure error
1. Flash the system
2. System board
001-040-XXXSystem IRQ failure
1. Power-off/on system and re-test
2. System board
001-041-XXXSystem DMA failure
1. Power-off/on system and re-test
2. System board
001-195-XXXSystem Test aborted by user
1. Information
2. Re-start the test, if necessary
001-196-XXXSystem test halt, error threshold
exceeded
1. Press F3 to review the log file
2. Re-start the test to reset the log file
001-197-XXXSystem test warning
1. Make sure the component that is called out is
connected and/or enabled
2. Re-run test
3. Component that is called out in warning statement
4. Component under test
001-198-XXXSystem test aborted
1. If a component is called out, make sure it is
connected and/or enabled
2. Flash the system and re-test
3. Go to the Undetermined problems section
Chapter 1. IBM PC Enhanced Diagnostics error codes 3