IBM 6569 Personal Computer User Manual


 
POST Error Code FRU/Action
107XCheck SCSI terminator installation
1. Check SCSI terminator installation
2. SCSI Cable
3. SCSI Terminator
4. SCSI Device
5. SCSI Adapter
1101Serial connector error, possible system board
failure
1. Run Enhanced Diagnostics
1101, 1102, 1106, 1108, 1109
1. System Board
2. Any Serial Device
1107
1. Communications Cable
2. System Board
1102Card selected feedback error
1. Run Enhanced Diagnostics
1103Port fails register check
1. Run Enhanced Diagnostics
2. System Board
1106Serial option cannot be turned off
1. Run Enhanced Diagnostics
2. System Board
1107
1. Serial Device Cable
2. System Board
1110Register test failed
1. Run Enhanced Diagnostics
2. System Board
1116Interrupt error
1. Run Enhanced Diagnostics
1117Failed baud rate test
1. Run Enhanced Diagnostics
1162 Serial port configuration error
1. Run Configuration
2. Serial Adapter
(if installed)
3. System Board
11XXNot listed above
1. System Board
1201
1. System Board
2. Any Serial Device
1202, 1206, 1208, 1209, 12XX
1. Dual Async Adapter/A
2. System Board
3. Any Serial Device
Chapter 2. Types 6568/6569/6648/6649 77