IBM 6569 Personal Computer User Manual


 
POST Error Code FRU/Action
1107
1. Serial Device Cable
2. System Board
1110Register test failed
1. Run Enhanced Diagnostics
2. System Board
1116Interrupt error
1. Run Enhanced Diagnostics
1117Failed baud rate test
1. Run Enhanced Diagnostics
1162 Serial port configuration error
1. Run Configuration
2. Serial Adapter
(if installed)
3. System Board
11XXNot listed above
1. System Board
1201
1. System Board
2. Any Serial Device
1202, 1206, 1208, 1209, 12XX
1. Dual Async Adapter/A
2. System Board
3. Any Serial Device
1207
1. Communications Cable
2. Dual Async Adapter/A
13XX
1. Game Adapter
1402Printer not ready Information only
1403No paper error, or interrupt failure Information only
1404System board timeout failure
1. Run Enhanced Diagnostics
1405Parallel adapter error
1. Run Enhanced Diagnostics
1406Presence test error
1. Run Enhanced Diagnostics
14XXNot listed above. Check printer before
replacing system board
1. Printer
2. System Board
15XX
1. SDLC Adapter
1692Boot sequence error
1. Run FDISK to ensure at least one active
partition is set active
16XX
1. 36/38 Workstation Adapter
1762Hard disk drive configuration error
1. Run Configuration. (See Setup Utility
program on page 122.)
158 Hardware Maintenance Manual: IBM NetVista Computer Types 6058, 6059, 6269, 6568, 6569, 6578, 6579, 6648,
6649