Diagnostic Error Code FRU/Action
000-039-XXX
BIOS DMI data error
1. Flash the system. See “Flash update
procedures” on page 148
2. System board
000-195-XXX
BIOS Test aborted by user
1. Information
2. Re-start the test, if necessary
000-196-XXX
BIOS test halt, error threshold exceeded
1. Press F3 to review the log file
2. Re-start the test to reset the log file
000-197-XXX
BIOS test warning
1. Make sure the component that is called
out is connected and/or enabled. See
Chapter 5, “Using the IBM Setup
Utility,” on page 19
2. Re-run test
3. Replace the component that is called out
in warning statement
4. Replace the component under test
000-198-XXX
BIOS test aborted
1. Make sure the component that is called
out is connected and/or enabled. See
Chapter 5, “Using the IBM Setup
Utility,” on page 19
2. Flash the system and retest. See “Flash
update procedures” on page 148
3. Go to “Undetermined problems” on page
89
000-199-XXX
BIOS test failed, cause unknown
1. Go to “Undetermined problems” on page
89
2. Flash the system and re-test
3. Replace component under function test
000-250-XXX
BIOS APM failure
1. Flash the system. See “Flash update
procedures” on page 148
2. System board
000-270-XXX
BIOS ACPI failure
1. Flash the system. See “Flash update
procedures” on page 148
2. System board
001-000-XXX
System Test Passed
1. No action
001-00X-XXX
System Error
1. System board
001-01X-XXX
System Error
1. System board
001-024-XXX
System Addressing test failure
1. System board
001-025-XXX
System Checksum Value error
1. Flash the system. See “Flash update
procedures” on page 148
2. System board
50 Hardware Maintenance Manual