Diagnostic Error Code FRU/Action
014-015-XXX
Parallel port External Loopback failure
1. Wrap plug
2. System board
014-027-XXX
Parallel port Configuration/Setup error
1. Run Setup, enable port
2. Flash the system. See “Flash update
procedures” on page 148
3. System board
014-03X-XXX
014-04X-XXX
Parallel port failure
1. System board
014-195-XXX
Parallel port Test aborted by user
1. Information
2. Re-start the test, if necessary
014-196-XXX
Parallel port test halt, error threshold
exceeded
1. Press F3 to review the log file
2. Re-start the test to reset the log file
014-197-XXX
Parallel port test warning
1. Make sure the component that is called
out is connected and/or enabled. See
Chapter 5, “Using the IBM Setup
Utility,” on page 19
2. Re-run test
3. Replace the component that is called out
in warning statement
4. Replace the component under test
014-198-XXX
Parallel port test aborted
1. If a component is called out, make sure
it is connected and/or enabled
2. Flash the system and re-test. See “Flash
update procedures” on page 148
3. Go to “Undetermined problems” on page
89
014-199-XXX
Parallel port test failed, cause unknown
1. Go to “Undetermined problems” on page
89
2. Flash the system and re-test. See “Flash
update procedures” on page 148
3. Replace component under function test
014-2XX-XXX
014-3XX-XXX
Parallel port failure
1. External parallel device
2. System board
015-000-XXX
USB port Interface Test Passed
1. No action
015-001-XXX
USB port Presence
1. Remove USB device(s) and re-test
2. System board
015-002-XXX
USB port Timeout
1. Remove USB device(s) and re-test
2. System board
015-015-XXX
USB port External Loopback failure
1. Remove USB device(s) and re-test
2. System board
Chapter 7. Symptom-to-FRU Index 57