IBM 8184 Personal Computer User Manual


 
Diagnostic Error Code FRU/Action
035-199-XXX
RAID interface test failed, cause unknown
1. Go to “Undetermined problems” on page
89
2. Flash the system and re-test. See “Flash
update procedures” on page 148
3. Replace component under function test
071-000-XXX
Audio port Interface Test Passed
1. No action
071-00X-XXX
071-01X-XXX
071-02X-XXX
Audio port error
1. Run Setup
2. Flash the system. See “Flash update
procedures” on page 148
3. System board
071-03X-XXX
Audio port failure
1. Speakers
2. Microphone
3. Audio card, if installed
4. System board
071-04X-XXX
Audio port failure
1. Run Setup
2. Audio card, if installed
3. System board
071-195-XXX
Audio port Test aborted by user
1. Information
2. Re-start the test, if necessary
071-196-XXX
Audio port test halt, error threshold
exceeded
1. Press F3 to review the log file
2. Re-start the test to reset the log file
071-197-XXX
Audio port test warning
1. Make sure the component that is called
out is connected and/or enabled. See
Chapter 5, “Using the IBM Setup
Utility,” on page 19
2. Re-run test
3. Replace the component that is called out
in warning statement
4. Replace the component under test
071-198-XXX
Audio port test aborted
1. If a component is called out, make sure
it is connected and/or enabled. See
Chapter 5, “Using the IBM Setup
Utility,” on page 19
2. Flash the system and re-test. See “Flash
update procedures” on page 148
3. Go to “Undetermined problems” on page
89
071-199-XXX
Audio port test failed, cause unknown
1. Go to “Undetermined problems” on page
89
2. Flash the system and re-test. See “Flash
update procedures” on page 148
3. Replace component under function test
071-25X-XXX
Audio port failure
1. Speakers
2. Audio card, if installed
3. System board
Chapter 7. Symptom-to-FRU Index 63