12 RS/6000 7025 Model F80 Technical Overview
Then add the adapter to the system. When finished, press Enter again to turn on
slot power. The hot-plug LED will change its state to On. Now the adapter is
integrated into the system and can be configured using AIX
cfgmgr (Configuration
manager).
Removal of adapters requires deconfiguration in AIX first. The adapter must be in
a defined state or removed from the ODM.
Figure 8 shows an example of adding a hot-plug PCI adapter to a running
system.
Figure 8. Example: Adding a Hot-Plug PCI Adapter
Software Requirements
The Model F80 requires AIX 4.3.3 with the AIX 4330-03 recommended
maintenance package (APAR IY09047), which is included on all pre-installed
systems and on the 04/2000 Update CD that ships with AIX 4.3.3 as of April
2000.
In addition, there is APAR IY09814, which includes additional fixes that were not
available before the 4330-03 package was shipped. In order to install the Model F80
from CD, you need an AIX 4.3.3 CD dated 04/2000 (LCD4-0286-05) or later,
because the system will not boot from older AIX 4.3.3 CDs. You can also
download the actual maintenance level from the Internet to install the machine
using NIM
2
. The URL to obtain the maintenance level is:
2
Network Installation Manager (NIM)
# lsslot -c pci
# Slot Description Device(s)
P1-I3 PCI 64 bit, 66 MHz, 3.3 volt slot Empty
P1-I4 PCI 64 bit, 66 MHz, 3.3 volt slot Empty
P1-I5 PCI 64 bit, 66 MHz, 3.3 volt slot ent1
P1-I6 PCI 64 bit, 50 MHz, 5 volt slot Empty
P1-I7 PCI 64 bit, 50 MHz, 5 volt slot Empty
P1-I8 PCI 64 bit, 66 MHz, 3.3 volt slot scsi2, scsi3
P1-I9 PCI 64 bit, 66 MHz, 3.3 volt slot Empty
P1-I10 PCI 64 bit, 66 MHz, 3.3 volt slot Empty
P1-I11 PCI 64 bit, 50 MHz, 5 volt slot ssa0
P1-I12 PCI 64 bit, 50 MHz, 5 volt slot Empty
# drslot -c pci -Ia -s P1-I6
The visual indicator for the specified PCI slot has
been set to the identify state. Press Enter to continue
or enter x to exit.
[Enter]
The visual indicator for the specified PCI slot has
been set to the action state. Insert the PCI card
into the identified slot, connect any devices to be
configured and press Enter to continue. Enter x to exit.
[Enter]