IBM H80 Series Personal Computer User Manual


 
Service Processor Error Logs
The service processor error logs, an example of which is shown below, contain error
conditions detected by the service processor.
Error Log
1. 11/3/99 19:41:56 Service Processor Firmware Failure
B14999
Enter error number for more details.
Press Return to continue, or 'x' to return to menu.
Press "C" to clear error log, any other key to continue. >
Note: The time stamp in this error log is Coordinated Universal Time (CUT), which
is also referred to as Greenwich Mean Time (GMT). AIX error logs have additional
information available and can time stamp with local time.
Entering an error number provides nine words of system reference code (SRC) data;
an example screen is shown below.
Detail: 65
SRC
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
word11:B14999 word12:115D word13:
word14: word15:1111 word16: 
word17:B14AAA word18:1145D word19:A4F1E99
B14999
Press Return to continue, or 'x' to return to menu.
If Return is pressed, the contents of NVRAM will be dumped 320 bytes at a time,
starting at address 0000.
Chapter 3. Using the Service Processor 75