IBM SG24-5131-00 Laptop User Manual


 
10 IBM Certification Study Guide AIX HACMP
Your slot configuration must also allow for the disk I/O adapters you need to
support the cluster’s shared disk (volume group) configuration. If you intend
to use disk mirroring for shared volume groups, which is strongly
recommended, then you will need to use slots for additional disk I/O
adapters, providing I/O adapter redundancy across separate buses.
The following table tells you the number of additional adapters you can put
into the different RS/6000 models. Ethernet environments can sometimes
make use of the integrated ethernet port provided by some models. No such
feature is available for token-ring, FDDI or ATM; you must use an I/O slot to
provide token-ring adapter redundancy.
Table 4. Number of Adapter Slots in Each Model
1
The switch adapter is onboard and does not need an extra slot.
RS/6000 Model Number of Slots Integrated Ethernet Port
7006 4 x MCA yes
7009 C10, C20 4x PCI no
7012 Mod. 3XX and GXX 4 x MCA yes
7013 Mod. 5XX 7 x MCA no
7013 Mod. JXX 6 x MCA, 14 x MCA
with expansion unit J01
no
7015 Mod. R10, R20, R21 8 x MCA no
7015 Mod. R30, R40, R50 16 x MCA no
7017 Mod. S7X 52 x PCI no
7024 EXX 5 x PCI, 1 x PCI/ISA 2 x
ISA
no
7025 F50 6 x PCI, 2 x ISA/PCI yes
7026 Mod. H50 6 x PCI, 2 x ISA/PCI yes
7043Mod. 3 x PCI, 2 x ISA/PCI yes
9076 thin node 4 x MCA yes
9076 wide node 7 x MCA no
9076 high node 15 x MCA no
9076 thin node (silver) 2 x PCI yes
1
9076 wide node (silver) 10 x PCI yes
1