3.2. Printer Configuration Procedure
1. Set the device address on the switch located on the rear panel
next to the twinax connector. Possible values are 0 to 6.
Make sure that the device address is set before the twinax cable
is connected.
2. Select PCL from the front panel.
3. Turn the printer power off before you connect the twinax
cable(s) according to Section 3.3, Twinax Connection.
4. The configuration must comply with the requirements of your
installation and the relevant print jobs.
To check the configuration of the printer, press the test key on the
rear panel once and the setup of the printer will be printed out.
NOTE:
When the ida 812-1x MIO is connected to an IBM
System AS/400, it must be defined as an IBM 3812
Model 1 printer from the host system in accordance
with the appropriate IBM documentation.
3.3. Twinax Connection
Before the twinax cable is connected, be sure to turn the printer
power OFF.
With power turned off, connect the auto-terminating T-cable to the
twinax socket at the rear of the ida 812-1x MIO, and turn the ring
clockwise to lock.
Connect the twinax cable(s) to the T-cable and turn the ring(s)
clockwise to lock.
Send data from the system and check the printout.