I-Data 812-1x MIO Network Card User Manual


 
ida 812-1x MIO Operator’s Guide
Installation
-16-
WARNING!
The twinax cable must never be connected directly to
the twinax socket of the printer. It must always be
connected to the T-cable.
3.4.
Printer Emulations
On the ida 812-1x MIO it is possible to emulate the following IBM
printers once the interface card has been installed:
3812-1/5219
5224-2
5225-2
5256 -120
4234-2
Factory default is 3812-1/5219 emulation. You change this emulation
in the following way (provided that the printer has been configured
as described in Section 3.2, Printer Configuration Procedure)
1. Turn printer power OFF and disconnect the twinax cable.
2. Press and hold the [TEST] key on the interface and turn printer
power ON.
3. When the printer is ready the following will be printed:
"Current emulation is xxxx"
4. Turn the Device Address switch on the rear panel to the required
value according to the following table:
VALUE EMULATION
0 3812-1/5219
1 5224-2
2 5225-2
3 5256-120
4 4234-2
5. Press the [TEST] key again and the selected emulation will be
printed.