I-Data 812-1x MIO Network Card User Manual


 
ida 812-1x MIO Operator’s Guide
Errors and Recovery
-31-
downloaded firmware again
No invalid boot ID
in HEX data
8E You have tried to
download a firmware not
meant for this product
Attempt to write to
boot area
90 Firmware code error. A
correction to the
firmware code is needed
Get correction to
firmware code
Attempt to write to
boot area
91 Firmware code error. A
correction to the
firmware code is needed
Get correction to
firmware code.
Unable to read
back Twinax code
AO Hardw0are error
Fig. 6-1 Error Messages in MIO Front Panel
6.2. Error Messages on Paper
Other than the error messages in the MIO front panel the
following error codes print on paper:
ERROR DESCRIPTION
Error 8011 Communication error/Hardware error
Error 4510 Invalid SCS Control received
Error 5004 Initializing NVRAM
Error 5005 NVRAM failed/Hardware error
Error 5006 NVRAM initialized
Error 50?? CP error
Fig. 6-2: Error Messages which are printed, if possible
6.3. Two Devices with Same Address
If two devices on the same twinax line have the same address,
the printer will print an error message.
Recovery:
1. Check each device on the same line against the system
configuration.
2. Change the device address accordingly as described in
Chapter 3. Installing the ida 812-1x MIO printer.