Intelligent Motion Systems IM481H Computer Drive User Manual


 
28
1 Ampere (Peak)
Length (Feet)
Minimum AWG
10 25 50* 75* 100*
20 20 18 18 16
2 Amperes (Peak)
Length (Feet)
Minimum AWG
10 25 50* 75* 100*
20 18 16 14 14
3 Amperes (Peak)
Length (Feet)
Minimum AWG
10 25 50* 75* 100*
18 16 14 12 12
4 Amperes (Peak)
Length (Feet)
Minimum AWG
10 25 50* 75* 100*
18 16 14 12 12
5 Amperes (Peak)
Length (Feet)
Minimum AWG
10 25 50* 75* 100*
16 16 14 12 12
6 Amperess (Peak)
Length (Feet)
Minimum AWG
10 25 50* 75* 100*
14 14 14 12 12
7 Amperess (Peak)
Length (Feet)
Minimum AWG
10 25 50* 75* 100*
12 12 12 12 12
* Use the alternate method illustrated in Example B
when cable length is
50 feet.
IMS Driver to Motor Cable AWG Table
Driver to Motor Supply Cable Wire Size
NOTE: These recommendations will provide optimal
protection against EMI and RFI. The actual cable type,
wire gauge, shield type and filtering devices used are dependent on
the customer’s application and system.
NOTE: Always use Shielded/Twisted Pairs for the IMS Driver
DC Supply Cable, the AC Supply Cable and the IMS Driver to
Motor Cable.