Intel SHG2 Computer Hardware User Manual


 
76 Intel Server Board SHG2 Product Guide
Using the Firmware Update Utility
The Firmware Update Utility is a DOS-based program used to update the Baseboard Management
Controllers firmware code. You only need to run the Firmware Update Utility if new firmware
code becomes necessary or the firmware becomes corrupted. It is highly recommended that you
also update the FRU/SDR files at the same time that you update the BMC Firmware.
You can obtain the latest version of the firmware update file from the Intel Customer Support
website:
http://support.intel.com/support/motherboards/server/SHG2
Making a BMC Firmware Update Diskette
1. Place a formatted diskette into the diskette drive.
2. Extract the contents of the SHG2 firmware file onto the diskette.
Making the Update Diskette Bootable
1. Use a DOS system to create the diskette or boot the server to the System Resource CD and
Quit to DOS.
2. Insert the update diskette into diskette drive A.
At the C:\ prompt, type:
sys a:
3. Press
<Enter>
Updating the BMC Firmware
In the event of a release of an updated BMC Firmware, the following procedure may be used to
update the firmware.
NOTE
These instructions for BMC Update are a general guideline. Please follow
the specific instructions described in the release notes.
1. Prepare a bootable floppy diskette containing the updated BMC firmware files for the
SHG2 Server Board obtained from:
http://support.intel.com/support/motherboards/server/SHG2
2. Insert the BMC Firmware floppy diskette into the disk drive.
3. Reboot the system. BMC Firmware update occurs automatically and may take several minutes
to complete. When the BMC Firmware update is complete, it is safe to power off the system.
4. Power off the system and remove the power cord for 30 seconds.
5. Connect the power cord and power on the system.