4.6 Random Vibration
Non-operating: 0.01 g²/Hz at 5 Hz, sloping to 0.02 g²/Hz at 20 Hz, and maintaining 0.02 g²/Hz from 20 Hz to
500 Hz. The area under the PSD curve is 3.13 gRMS. The duration shall be 10 minutes per axis for all three
axes on all samples.
4.7 Acoustics
Sound Power: The power supply assembly shall not produce a declared sound power level greater than 3.8
BA. Sound power determination is to be performed at 43C, 50% of rated load, at sea level. This test point is
chosen to represent the environment seen inside a typical system at the idle acoustic test condition, with the
43C being derived from the standard ambient assumption of 23C, with 20C added for the temperature
rise within the system (what is typically seen by the inlet fan). The declared sound power level shall be
measured according to ISO 7779 and reported according to ISO 9296.
Pure Tones: The power supply assembly shall not produce any prominent discrete tone determined
according to ISO 7779, Annex D.
4.8 Ecological Requirements
The following materials must not be used during design and/or manufacturing of this product:
Cadmium shall not be used in painting or plating.
Quaternary salt and PCB electrolytic capacitors shall not be used.
CFCs or HFCs shall not be used in the design or manufacturing process.
Mercury shall not be used.