Juniper Networks ERX-1440 Network Router User Manual


 
Connection Information
ERX Edge Routers
B-13
GE
single mode
b
GE/FE GE
I/O
SINGLE
MODE
1 active
1 redundant
SC full duplex Tx power
min: –11 dBm
max: –3 dBm
Center wavelength: 1300 nm
Rx input power
min: –20 dBm
max: –3 dBm
Rated for 550 m (601 yards)
over 62.5-micron core or
50-micron core MM fiber
Rated for 5 km (3.1 miles)
over 10-micron core cable
HSSI HSSI-3F HSSI-3 3 Standard HSSI
connector: 2-row,
50-pin, receptacle
header with rails and
latch blocks
50 feet (15.24 m) maximum
cable length
IPSec Service IPSEC
SERVICE
No I/O
module
N/A N/A N/A
OC3 (dual
port)
multimode
OC3 OC3
I/O
MULTI
MODE
2 SC full duplex Tx power:
min: –19 dBm
max: –14 dBm
Center wavelength: 1310 nm
Rx input power:
min: –30 dBm
max: –14 dBm
Rated for 2 km (1.2 miles)
over 62.5-micron core cable
with an optical loss of 0–9 dB
or 50-micron core cable with
an optical loss of 7 dB
OC3 (dual
port)
single mode
OC3 OC3
I/O
SINGLE
MODE
2 SC full duplex Tx power:
min: –15 dBm
max: –8 dBm
Center wavelength: 1310 nm
Rx input power:
min: –31 dBm
max: –8 dBm
Rated for 15 km (9.3 miles) of
9-micron core cable
Table B-3 Connection information for module assemblies (continued)
Assembly
Name and
Capability
Line
Module
Label
I/O Module
Label
No. of
Ports
Connector Type Cabling Specifications