Konica Minolta A034011 Printer User Manual


 
Indicator Messages7-6
* Differs depending on the toner status.
On Off Rapid
blinking
The installed toner
cartridge is of an
unapproved type.
Install a KONI-
CAMINOLTA toner
cartridge of the
appropriate type
(AM, EU, AP or
GC).
See page 5-3.
Blinking Off On Toner out
" This message
appears when
the Toner Out
Stop in the
Remote Panel
Utility is set to
Off.
Replace the toner
cartridge.
" Printing can
continue,
however,
the printing
results are
not
guaranteed.
On Slow
blinking
* Imaging cartridge
near end
Prepare the new
imaging cartridge.
* Toner cartridge mem-
ory error
Re-install the
specified toner
cartridge.
* Video interface error Turn off the
printer. After a few
seconds, turn on
the printer.
* Process caution Open and close
the printer’s cov
-
ers.
If the error is not
corrected, turn off
the printer. After a
few seconds, turn
on the printer.
Off Slow
blinking
* Imaging cartridge end Replace the imag-
ing cartridge.
Ready
indicator
(green)
Error
indicator
(orange)
Toner
indicator
(orange)
Condition Action