Konica Minolta MS6000 MKII Scanner User Manual


 
2. Initial Settings
4-11
Miscellaneous
Chapter 4
U8: Total Scan Counter
The number of scan sequences carried out by the Scanner can be displayed with this func-
tion.
1. Select U8 in the User mode.
2. Press the Start key.
The number of scan sequences so far carried out by the Scanner is displayed.
The following display represents that the scan count is 24,612.
System Settings by the dealer
System Settings Description Selection Initial Setting
Auto reset Setting changes made to the control panel
that are not used within 60 seconds of
being input are automatically cancelled
and the system reverts back to the original
settings.
Enabled * (200V)
Disabled * (120V)
Auto Power Save
ON/OFF
Sets the unit to enable or disable the Auto
Power Save mode.
* For USA and Canada (120V area), the
Auto Power Save mode becomes avail-
able only if the Energy Star Kit is
mounted on the Scanner.
Enabled
Disabled
* (200V)
* (120V)
Printer Heater
OFF (PR mode
only)
Turns the Printer’s heater OFF if the sys-
tem is left idle for a specific period of
time.
* Priority is given to the Power Save
mode, if Power Save has been set.
Disabled
30 min. *
60 min.
Auto Projection
Lamp OFF
Turns the Scanner’s Projection Lamp OFF
if the system is left idle for a specified
period of time.
* Priority is given to the Power Save
mode, if Power Save has been set.
Disabled *
30 min.
60 min.
Fine mode con-
trast select
Applies the following functions as required:
Contrast Emphasis: applied when film con-
tains text that is poorly contrasted against its
background making it difficult to read.
Outline Emphasis: applied when film con-
tains blurred black and white images.
Contrast
Emphasis
*
Outline
Emphasis