ETS Installation Guide
60
E
E
:
:
S
S
p
p
e
e
c
c
i
i
f
f
i
i
c
c
a
a
t
t
i
i
o
o
n
n
s
s
Power Information
Power Requirements
Voltage: 95 - 250 Volts AC, 3-wire single phase, auto-ranging
Frequency: 47-63 Hz
Operating Current: 300 mA @ 120 V
Power Consumption: 40 Watts (maximum)
Fuse Rating: 1.6A, 250 Volts
Power Supply Cord
Cord type: 3 conductors, 1.0 mm2 minimum conductor size
(approximately 18 AWG)
Rated for: 250 Volts AC, 10 Amps
Length: 3.0 meters
Environmental Limitations
Temperature
Operating range: 5° to 50° C (41° to 122° F)
Storage range: -40° to 66° C (-40° to 151° F)
Max temp. change/hr: 20° C (36° F)
Rapid temperature changes may affect operation. Therefore, do not operate the ETS
near heating or cooling devices, large windows, or doors that open to the outdoors.
Altitude
Operating maximum: 2.4 km (8,000 ft)
Storage maximum: 9.1 km (30,000 ft)
If operating the ETS above 2.4 km (8000 ft.), decrease the operating temperature
rating by 1° F for each 1000 ft.
Relative Humidity
Operating range: 10% to 90% noncondensing, 40% to 60%
recommended
Storage range: 10% to 90% noncondensing