4: Using Setup Mode for Configuration
XPort™ User Guide 33
The character string ATH is received, terminated with a carriage return. The
unit responds affirmatively according to the selected echo/response mode
and drops the network connection. The serial interface reverts to accepting
command strings.
If this sequence is not followed, the unit remains in data transfer mode.
Table 4-12. Modem Mode Commands
Modem Mode
Command
Function
ATDTx.x.x.x,pppp or
ATDTx.x.x.x/pppp
Makes a connection to an IP address (x.x.x.x) and a remote port
number (pppp).
ATDTx.x.x.x
Makes a connection to an IP address (x.x.x.x) and the remote port
number defined within the unit.
ATD0.0.0.0
Forces the unit into Monitor Mode if a remote IP address and port
number are defined within the unit.
ATD
Forces the unit into Monitor Mode if a remote IP address and port
number are not defined within the unit.
ATDx.x.x.x
Makes a connection to an IP address (x.x.x.x) and the remote port
number defined within the unit.
ATH Hangs up the connection (Entered as +++ATH ).
ATS0=n
Enables or disables connections from the network going to the serial
port.
n=0 disables the ability to make a connection from the network to the
serial port.
n=1-9 enables the ability to make a connection from the network to
the serial port.
n>1-9 is invalid.
ATEn
Enables or disables character echo and responses.
n=0 disables character echo and responses.
n=1 enables character echo and responses.
ATVn
Enables 1-character response or full verbose.
n=0 enables 1-character response.
n=1 enables full verbose.
Note: The unit recognizes these AT commands as single commands such as
ATE0 or ATV1; it does not recognize compound commands such as ATE0V.
Remote IP Address
This is the destination IP address used with an outgoing connection.
Remote Port
You must set the remote TCP port number for the unit to make outgoing connections.
This parameter defines the port number on the target host to which a connection is
attempted.