Page 45 Digital Display Wall Clock Guide DDC2 / 4-RS -24 Wiring
DDC2-RS-24 / DDC4-RS-24 Wiring
H
M
O
P
E
N
1
2
3
4
5
6
7
8
Set switches 1-5 of S1 as shown.
Indicates depressed side of switch
To
Other Clocks
24VAC
From
Master Clock
BLU / WHT
Run
Correction
BRN / WHT
BLK
BLK
AC Return