Lathem LTR8-512 Time Clock User Manual


 
LTRx-512 Installer’s Guide
14
[#] SYSTEM TYPE CODE: NN
If you are using an LTR8-512 or LTR8-512M and you chose a
CLOCK1 type other than 00, you will see
SELECT CLK2 CODE: NN
[0]..[9] Enter the code for CLOCK2, or 00, if none
[#] PRESS [#] IF CORRECT
[#] Press [#] to accept
-or-
[*] Press [*] to cancel and try again
Manual Bell Control
Use Function [3] to manually turn on bell circuits
Press Display
[#] SELECT FUNCTION CODE
[3] [3]=MANUAL BELL CTRL
[#] MANUAL BELL CONTROLS
1-2-3-4-5-6-7-8
PRESS AND HOLD [#]
TO EXECUTE.[*]TO END
[1]..[8] Enter the circuit numbers that you want to test. When you see the
circuits you want, press and hold [#]. Those circuits will turn on
their relays, as shown by the green panel lights. When you release
the [#], the circuits will turn off their relays. You can now choose
and test other circuits or press [*] to quit
Note: Only circuits setup as Bell Zones will appear. If you have an
LTR8-512 with a single clock system attached, you will only see
circuits 1-6. If you have an LTR4-512 with a single clock system
attached, you will only see circuits 1-2
[*] Return to time and date display