Table 20. Submenus under the Hardware Health Conguration (continued)
Item Option Description
H/W Health Function Disabled / [Enabled]
Enable or disable the hardware
monitor function.
Auto FAN Control Disabled / [Enabled]
If this option is set to Disabled, the
fan runs at the full speed; if this option
is set to Enabled, the fan speed is
controlled by the system temperature.
PWM Minimal Duty Cycle [60% Duty Cycle] / 45% Duty Cycle
/ 30% Duty Cycle
Select the PWM Minimal Duty Cycle
for the fan: 60%-100%, 45%-100%,
or 30%-100%.
Fan Failure LED Indication
Disabled / [Enabled]
Enable or disable the fan alarm
function. If this option is set to
Enabled, a message about fan failure
will be displayed on the POST screen
when the rotational speed of each fan
is less than 800 rpm.
Hardware Health Event Monitoring
Read Only
The sensor data in this option is for
read only. The detected data includes
the temperature and system fan
rotational speed.
Note: The settings in [ ] are the default settings in the Setup Utility program.
Table 21. Submenus under the IPMI 2.0 Conguration
Item Sub-item Option Description
View BMC System Event
Log
View the system event log.
Clear BMC System Event
Log
Delete the system event
log.
Set LAN Conguration Set the IP address source,
IP address, subnet mask,
and gateway address.
Set PEF Conguration PEF SUPPORT Disabled / [Enabled]
Enable or disable the PEF
support.
BMC Watch Dog Timer
Action
[Disabled] / Reset System /
Power Down / Power Cycle
Disable or enable the OS
based dongle. If enabled,
whenever any problems
arising from the operation
system, such as the
system halted, the system
management feature will
take actions of Reset
System, Power Down, or
Power Cycle at the prompt
of the dongle Timer.
BMC Alert LED and Beep [Off] / On Turn on or turn off the BMC
alert LED and beep.
FW key
[0000000]
Note: The settings in [ ] are the default settings in the Setup Utility program.
72 ThinkServer Installation and User Guide