8. When the USB ServerSwitch has received the entire file, it will
prompt the user through the serial port to confirm that the file is
correct. Check the file version to be certain that it is the version that
you wish to upload to the USB ServerSwitch system.
9. When ready to modify the flash, select 'y' for 'continue with
programming'. NOTE: DO NOT TURN THE POWER OFF at this
point.
10. The flash memory will be erased, and the new flash file will then be
saved.
11. You will get a prompt stating "Flash Programming Complete" after
less than a minute. Finally, it will state "Starting System".
12. After you see the Starting System prompt, the Flash update is
completed, and the USBSS is ready to go. Simply disconnect your
PC from the CONTROL IN port, and return all connections to normal.
13. To verify that the System Flash has been updated, go to the Main
Menu, select the System Setup screen and see the version number
as listed on the screen.
14. You may also verify the System Flash version by pressing and
holding both front panel buttons for more than 3 seconds. The front
panel display will change to a diagnostic mode (during which time the
system in inoperative) and list the system firmware version. You
MUST exit this diagnostic mode by pressing both front panel buttons
for more than 3 seconds again, in order to return the unit to service.
Start XMODEM transfer of USB ServerSwitch flash memory
c c c c c c c c c c
Received: USB ServerSwitch v2.04
Continue with programming? (y/n) y
Erasing the flash (takes about 10 sec.)
Programming FLASH ...........................................................
Flash programming complete.
Starting System.