Linksys EPSX3 Printer User Manual


 
EtherFast 10/100 PrintServers
Click the NetBEUI tab to view or change the PrintServer’s NetBEUI connec-
tion settings.
Enter the name of the domain that you want the PrintServer associated with in
the Domain Name field. If you are unsure of the Domain Name, you can find
it by looking on any computer already on the network. In Windows 95, 98, and
NT, right click Network Neighborhood and select Properties. Under the
Identification tab, there will be listed that computer’s name, and the Domain to
which it is connected. For Windows Millennium and 2000, right click My
Network Places. Then right click Local Area Connection and choose
Properties. Then right click TCP/IP and choose Properties. The Domain
name will appear. If you want the PrintServer to be connected to that same
Domain, enter that Domain name here. If no Domain name exists there, you
will use the Workgroup name from that window.
Under Options, you can also specify the Response Time that you prefer for the
PrintServer. This is the amount of time (measured in seconds) that the
PrintServer will wait for a response from the network before “timing out”.
You also have the option to Abort Print Job if Error. Selecting Ye s here will
terminate the printing if there is an error of any kind. If you select No, print
jobs that have errors will be sent to the printer, but may not print properly.
If you make any mistakes prior to saving, click the Cancel button to exit the
screen without making any changes. Once you are certain of any changes you
have made, click the Save button to implement the changes.
The NetBEUI Page
29
Figure 8-3
Note: Linksys does not provide technical support for the NetBEUI
protocol.
28
Click the Logical Printers tab to view or change the PrintServer’s logical
printer settings.
For each Logical Printer, the following fields are available:
Logical Printer(Port) Select the Logical Printer Port you wish to config-
ure (L1 to L8). Click the Get Data button to update the display with the cur-
rent data for the selected logical printer.
Port Select the Printer Port used by the Logical printer.
Pre-string The printer control string (in hex) to be sent to the printer before
each print job. This string cannot exceed 30 characters.
Post String The printer control string (in hex) to be sent to the printer after
each print job. This string cannot exceed 30 characters.
Convert LF to CR+LF If checked, LF (line feed) characters are changed to
CR+LF (carriage return and line feed).
If you make any mistakes, click the Cancel button to exit the screen without
making any changes. Once you are certain of any changes you have made,
click the Save button to implement the changes.
The Logical Printers Page
Instant EtherFast
®
Series
Figure 8-2
Note: Linksys does not provide any technical support for logical print-
ers configuration.