Lucent Technologies 9077 16S Network Router User Manual


 
B-10 October 22, 1999 SP Switch Router Adapter Guide - 1.4 Update 2
Log Messages
Message descriptions
“RX: got TBIC INITED fron TX.”
LOG_FILE: /var/log/gr.console
SOURCE_FILE: rx/tbsi_ipc.c
SCOPE: CARD
CONTEXT: RUNNING
SEVERITY: INFO
DESCRIPTION: Logged when the TX-CPU has initialized the Transmit TBIC.
“RX: Port connected, stat=0x%x.”
LOG_FILE: /var/log/gr.console
SOURCE_FILE: rx/tbsi_rc.c
SCOPE: CARD
CONTEXT: RUNNING
SEVERITY: INFO
DESCRIPTION: Logged when the Receive TBIC’s receive port is connected to the
switch chip’s send port.
“RX: send SEND_TOD to the switch.”
or
“RX: Reading TBIC's TOD .”
LOG_FILE: /var/log/gr.console
SOURCE_FILE: rx/tbsi_svc.c
SCOPE: CARD
CONTEXT: RUNNING
SEVERITY: INFO
DESCRIPTION: Historically, these messages were used to aid debugging between the
switch manager and the card.
“RX-TBIC outage error(s) detected IER1=0x%x, IER2=0x%x..,”
LOG_FILE: /var/log/gr.console
SOURCE_FILE: rx/tbsi_svc.c
SCOPE: CARD
CONTEXT: RUNNING
SEVERITY: FATAL
DESCRIPTION: This message is logged when a TBIC outage error occurs. The TBICs
are reset and the state machine goes back to CONFIGURED state. The SP Switch Router
Adapter card treats TBIC outage errors as permanent errors.
“RX-TBIC permanent error(s) detected IER1=0x%x, IER2=0x%x..,”
LOG_FILE: /var/log/gr.console
SOURCE_FILE: rx/tbsi_svc.c
SCOPE: CARD
CONTEXT: RUNNING
SEVERITY: FATAL
DESCRIPTION: This message is logged when a TBIC permanent error occurs. The
TBICs are reset and the state machine go back to CONFIGURED state.