Lucent Technologies M770 Switch User Manual


 
Cajun M770 Manager User’s Guide 45
Appendix B
Configuration Fields
Field Name Description
Activity Status The port activity status:
Active
- The port is enabled, and data is
transferred through the port.
Dormant
- The port is enabled, but data is not
transferred through it, e.g., because the port acts
as the backup port in a pair of redundant ports.
NotActive
- The port is disabled.
Administration Status The state of the port:
Enabled
- The port is enabled and can transmit
and receive packets.
Disabled
- The port is disabled and cannot
transmit or receive packets.
Auto Negotiation The configured state of the Auto-Negotiation
protocol between two stations. When enabled,
Auto-Negotiation detects the highest common
denominator for the flow control capabilities of the
endstations, and sets both to the same highest
common setting. It also delivers remote link status.
For more information, refer to
Auto-Negotiation
in
The Reference Guide
.
Clock Admin State The administered clock synchronization state of the
M-SPS module. Possible states are:
enable
- Clock synchronization is enabled on
the device.
disable, use Internal Clock
- Clock
synchronization is disabled on the M-SPS
module. The M-SPS module uses its internal
low accuracy (
±
20 ppm) oscillator.