Lucent Technologies M770 Switch User Manual


 
46 Cajun M770 Manager User’s Guide
Clock Status The status of clock synchronization on the device.
Possible statuses are:
locked
- The M-SPS module is using a clock
which is locked to the input timing source.
holdover
- The M-SPS module is simulating a
clock to which it was previously locked. This
state will last until the clock source is fixed.
free_running
- The M-SPS module is using its
±4.6 ppm oscillator to generate timing. This only
occurs after a reset when there are no healthy
timing sources available or when all four
sources are disabled.
internal
- Clock synchronization is disabled and
the M-SPS module is using its low accuracy
(±20 ppm) internal oscillator to generate timing.
Configuration Symbol For Module Configuration: The version of the
module. The version is updated whenever there is a
functional modification to the module.
For Agent Configuration: The version of the
hardware and firmware of the agent.
Connected To The DomainX to which the selected module is
connected -
DomainXL
for the left DomainX and
DomainXR
for the right DomainX.
Current Source The current source clock used for clock
synchronization. Possible sources are:
ATM A
/
B
- An ATM port on the device.
SYNC A
/
B
- An external source connected to the
front panel of the M-SPS.
none
- No recognizable clock source.
Device Type The device type.
Domain Resource Units The number of Domain Resource Units for the
module.
DomainX Configuration The configuration of the backplane of the Ethernet
switch in the device.
Faults A list of faults.
Field Name Description